The Flow — Conformité réglementaire

Cette page rassemble les informations réglementaires de The Flow (IoT Suction Machine), conformément à la directive 2014/53/UE (RED), à la directive 2011/65/UE (RoHS), à la directive 2012/19/UE (DEEE), à la partie 15 des règles FCC et aux exigences d'ISDE Canada.

Identification du produit

Nom du produitIoT Suction Machine
Nom commercial / modèleThe Flow
Version matérielle (HVIN)4
Version logicielle0.1
Numéro de sérieUUIDv7 unique
FCC ID2BQ5J-THEFLOW
IC34592-THEFLOW
Alimentation15 VAC, 50/60 Hz, 3000 mA
Adaptateur secteurXY-15003000AG (UE) / XY-15003000AB (UK) / XY-15003000AU (US-Canada)
UsageUsage intérieur uniquement

Opérateurs économiques

Fabricant
Laboratoire Gibro SA
Entre-deux Rivières 10, 2114 Fleurier, Suisse
[email protected] — +41 32 552 02 90

Représentant autorisé dans l'Union européenne (règlement (UE) 2019/1020, art. 4)
Phytobiodermie SAS
20 rue du Chasnot, 25000 Besançon, France
+33 3 39 88 01 17

Pays d'origine : France (assemblage final).

Déclaration UE de conformité

Par la présente, Laboratoire Gibro SA (Entre-deux Rivières 10, 2114 Fleurier, Suisse) déclare que le type d'équipement radio The Flow est conforme à la directive relative aux équipements radioélectriques (2014/53/UE) et à la directive RoHS (2011/65/UE, telle que modifiée par 2015/863).

Déclaration signée à Fleurier (Suisse) le 29 septembre 2025 par Camille Blardone, Regulatory Compliance Officer.

Normes harmonisées appliquées

Exigence essentielleNorme appliquéeRapport
Article 3.1(a) — SantéEN IEC 62311:2020CHTW25080040
Article 3.1(a) — SécuritéIEC 60335-2-23:2016/AMD1:2019 avec IEC 60335-1:2010/COR1:2010/AMD1:2013/COR1:2014/AMD2:2016/COR1:2016CHTE25080064
Article 3.1(b) — CEMETSI EN 301 489-1 V2.2.3 ; ETSI EN 301 489-17 V3.3.1 ; EN 55032:2015/A11:2020 ; EN 55035:2017/A11:2020 ; EN IEC 61000-3-2:2019/A1:2021 ; EN 61000-3-3:2013/A2:2021CHTW25080039
Article 3.2 — RadioETSI EN 300 328 V2.2.2CHTW25080037, CHTW25080038

Évaluation de la conformité

Auto-évaluation au titre de l'article 17(1) de la directive 2014/53/UE et de l'article 4 de la directive 2011/65/UE. Organisme notifié : aucun.

Bandes de fréquences et puissance d'émission

Information requise par l'article 10(8) de la directive 2014/53/UE.

BandePlage de fréquencesPuissance maximale (PIRE)
Bluetooth LE (1 Mbps)2402–2480 MHz8,55 dBm
Bluetooth LE (2 Mbps)2402–2480 MHz8,54 dBm
Wi-Fi 2,4 GHz2412–2472 MHz19,86 dBm

Aucune restriction de mise en service ni exigence d'autorisation d'utilisation dans les États membres de l'Union européenne.

États-Unis — FCC

FCC ID : 2BQ5J-THEFLOW

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

Canada — ISDE / ISED

IC : 34592-THEFLOW — CAN ICES-3 (B) / NMB-3 (B)

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device.

L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : 1) L'appareil ne doit pas produire de brouillage ; 2) L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

RoHS

The Flow est conforme à la directive 2011/65/UE relative à la limitation de l'utilisation de certaines substances dangereuses dans les équipements électriques et électroniques, telle que modifiée par la directive déléguée (UE) 2015/863. Rapport d'essai : CHTW25080041.

DEEE — collecte et recyclage

Le symbole de la poubelle barrée apposé sur le produit indique que, conformément à la directive 2012/19/UE, cet équipement ne doit pas être jeté avec les ordures ménagères en fin de vie. Il vous appartient de le remettre à un point de collecte agréé pour le recyclage des équipements électriques et électroniques. Cette collecte séparée contribue à préserver les ressources naturelles et à éviter les effets nocifs sur la santé humaine et l'environnement.

Rapports d'essais

Essais réalisés par Shenzhen Huatongwei International Inspection Co., Ltd. (HTW).

La documentation technique est conservée par le fabricant pendant dix ans à compter de la mise sur le marché du dernier exemplaire.

Contact conformité

Toute demande relative à la conformité de ce produit, y compris la fourniture du texte intégral de la déclaration UE de conformité, peut être adressée à :
Laboratoire Gibro SA — [email protected] — +41 32 552 02 90
ou au représentant autorisé dans l'Union : Phytobiodermie SAS, 20 rue du Chasnot, 25000 Besançon, France.